The new UPSI-2415DP3 DC UPS „Made in Germany“ ensures a reliable uninterruptible supply with 24V / 15A (360W) using safe LiFePO4 battery technology. With up to 6,000 cycles, an optimised charging process and comprehensive protection mechanisms, the robust DC UPS guarantees maximum fail-safety – even under demanding industrial conditions. The compact UPS solution for DIN rail mounting is ideal for critical infrastructure, Smart City and industrial applications.
With USB-C and RS485 Modbus interfaces, monitoring, control and integration into existing systems can be easily realised. The combination of long service life, fast charging capability and approvals according to IEC/UL/CSA 61010-1 and 61010-2-201 makes the UPSI-2415DP3 the ideal 24V DC UPS solution for networked and safety-critical applications.
The UPSI-2415DP3 enables uninterruptible operation or a controlled shutdown of embedded IPCs, controllers, network and communication technology, sensors as well as measurement, control and safety technology in control cabinets and decentralised systems in the event of a power failure.
The integrated high-performance LiFePO4 battery pack excels in safety-relevant applications. With up to 10 years of service life and stable battery chemistry, lithium iron phosphate technology offers maximum safety and virtually eliminates the risk of thermal runaway. The specially developed Battery Management System (BMS) ensures additional protection and high reliability. The optimised charging process provides significantly shorter charging times.
Front-mounted USB-C and RS485 Modbus interfaces as well as a configurable relay contact enable seamless integration into existing control environments and convenient configuration and monitoring via UPScom software.
In the event of a „power fail“, the UPS signals the voltage loss and can initiate a controlled shutdown of an IPC system if required, in order to protect valuable data. Once the supply voltage returns, the UPS reboot function automatically restarts the computer.
The robust DC UPS ensures reliable operation even in electromagnetically demanding environments due to its high immunity to burst and surge events (EN 61000-4-4 / -4-5). Comprehensive protection functions – including reverse polarity, short circuit, and overcurrent protection – ensure maximum operational safety and a long service life.
- DC UPS 24V / 15A "Made in Germany"
- Intrinsically safe LiFePO4 high-performance battery with up to 6,000 cycles
- Operating temperature range -20…+50°C
- Compact aluminium housing for DIN rail
- USB-C and RS485 Modbus interface
- Battery start function
- Intelligent power distribution
- Regulated output voltage in backup mode
- Minimum load detection
- Power failure timer function
- Relay contact for power fail
- Plug&Play – OS recognises UPS
- Extended functionality with included UPScom management software
- Shutdown&Reboot function
- Increased immunity for Surge&Burst
- Comprehensive protection functions
- Safety approval IEC/EN/UL 61010-1 / -2-201
- Available immediately from stock
The completely redesigned UPS management software is now available for free download.

Intuitive user interface and extensive functionality
The software 'UPScom' allows the connected devices to be shut down and switched off in a controlled manner during a power failure in order to avoid data loss or damage. The responsive WEB UI is called up in a web browser to set and pre-program all parameters of the DC UPS system and for real-time monitoring with state-of-charge indicator. The adjustable parameters include, among other things, load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, notifications by email.
Cross platform technology
'UPScom' uses the new WebAssembly (WASM) architecture, which runs in most current web browsers. 'UPScom' runs on x86 compatible systems and also on most ARM-64 based systems under Microsoft® Windows and various Linux distributions.
Secure Shutdown & Reboot function for IPC systems
In the event of a "power failure", the UPS signals the failure of the supply voltage via the integrated USB or RS232 interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. A script (batch) can also be executed before the system is shut down in order to process your own application-relevant processes. The integrated reboot function of the DC UPS automatically restarts the supplied IPC after the supply voltage returns, without the need for time-consuming on-site intervention by a service employee, e.g. in the case of completely self-sufficient computer systems at inaccessible locations.
Email messenger service
'UPScom' can be used for various events such as loss of connection to the UPS, system shutdown or power failure. These preventative measures can reduce or eliminate downtime.